Details, Fiction and high performance liquid chromatography
Details, Fiction and high performance liquid chromatography
Blog Article
HPLC works pursuing The fundamental basic principle of slim layer chromatography or column chromatography, where by it's got a stationary phase and a cellular stage. The mobile section flows throughout the stationary period and carries the elements on the mixture with it.
The cellular stage’s flow price is determined from the put together speeds of the two pumps. By changing the relative speeds of the two pumps, various binary cellular phases could be organized.
試料を注入する部分で、手動式(マニュアルインジェクター)と自動式(オートインジェクター)がある。
物質の電気化学的な性質を利用した検出器。pHの変動や酸化還元電位の変動を用いて測定を行う。
Various other detectors are actually Utilized in HPLC. Measuring a change while in the cell period’s refractive index is analogous to monitoring the cellular stage’s thermal conductivity in fuel chromatography. A refractive index detector is nearly common, responding to Pretty much all compounds, but has a relatively lousy detection limit of 0.
シリカゲルの粒子径が小さければ小さいほどピークの分離性は良くなるが、送液に必要なポンプの圧力が高くなる。そのため、ポンプ-インジェクター間、インジェクター-カラム間の配管の耐圧を上げたり、カラム自体を比較的高温の下にさらして溶媒の粘度を下げ、抵抗を小さくする工夫をしている。
The column is filled with a stationary phase content. The choice of column and stationary section depends upon the character of the compounds remaining analyzed and also the separation objectives.
The running stress inside an HPLC is sufficiently high that we cannot inject the sample into the click here cellular period by inserting a syringe through a septum, as is possible in gasoline chromatography. Instead, we inject the sample utilizing a loop injector
Modifying the cell phase’s polarity index changes a solute’s retention element. As we discovered in Chapter 12.three, however, a change in k just isn't a highly effective way to boost resolution if the Preliminary worth of k is larger than ten.
High-performance click here liquid chromatography (HPLC) is a robust analytical procedure for separating and determining factors in a mix. Obtaining accurate and reliable success needs mindful consideration to every phase from the Investigation, from sample preparation to knowledge interpretation.
The stationary section is frequently a solid help packed inside a column, Whilst the mobile stage is generally a liquid or a combination of liquids.
Degassing is completed in quite a few strategies, but the commonest are using a vacuum pump or sparging with an inert gasoline, which include He, which has a small solubility within the cellular section. Particulate elements, which may clog the HPLC tubing or column, are eradicated by filtering the solvents.
Right after loading the sample, the injector is turned into the inject place, which redirects the cellular section throughout the sample loop and on to the column.
Along with the Investigation approach understood, let us address prevalent concerns that may occur and the way to troubleshoot them.